INVESTIGATION OF ELECTRO-MECHANICAL FACTORS EFFECTING PIEZOELECTRIC ACTUATOR FOR VALVELESS MICROPUMP CHARACTERISTICS

Clicks: 348
ID: 92255
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #6 of 10 articles by views in journal of engineering science and technology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
In this study, a new micropump was designed, which is suitable for medical applications regarding size and flow rate. When a micropump is used to control the amount of drug delivery, the flow rate is a key parameter and can be controlled with the diaphragm displacement. The amount of displacement depends on the thickness of the piezoelectric element, voltage, and input frequency. The simulation results showed that the displacement of the vibrating diaphragm increased with applied voltage. Moreover, when the piezoelectric thickness was increased, vibrating diaphragm displacement also was decreased. The flow rate can be adjusted by increasing or decreasing of the input voltage. Presented results also showed that the performance of the micropump was affected by the frequency of voltage. In this study, we analysed two Lead Zirconate Titanate (PZT-2) piezoelectric actuators with 50 μm and 100 μm thicknesses. The voltage values were 10 V, 20 V, 30 V, 40 V and the frequencies were 5 Hz and 10 Hz, for 3 seconds with 1 ms sensitivity. The maximum flow rate was obtained at a 50 μm thickness of PZT and its value was 3.01E-30 m3/s and the maximum displacement of the diaphragm was 1.3962 μm at 40 V and 5 Hz. Thus, the frequency and net flow rate showed an inverse correlation.
Reference Key
dereshgi2018investigationjournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors DERESHGI, HAMID ASADI;YILDIZ, MUSTAFA ZAHID;
Journal journal of engineering science and technology
Year 2018
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.