Intervention to Reduce Interobserver Variability in Computed Tomographic Measurement of Cancer Lesions Among Experienced Radiologists.
Clicks: 365
ID: 91406
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
78.7
/100
365 views
253 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #1 of 2 articles by views in current problems in diagnostic radiology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
While a growing number of research studies have reported the inter-observer variability in computed tomographic (CT) measurements, there are very few interventional studies performed. We aimed to assess whether a peer benchmarking intervention tool may have an influence on reducing interobserver variability in CT measurements and identify possible barriers to the intervention. In this retrospective study, 13 board-certified radiologists repeatedly reviewed 10 CT image sets of lung lesions and hepatic metastases during 3 noncontiguous time periods (T1, T2, T3). Each preselected case contained normal anatomy cephalad and caudal to the lesion of interest. Lesion size measurement under RECISTS 1.1 guidelines, choice of CT slice, and time spent on measurement were captured. Prior to their final measurements, the participants were exposed to the intervention designed to reduce the number of measurements deviating from the median. Chi-square test was performed to identify radiologist-dependent factors associated with the variability. The percent of deviating measurements during T1 and T2 were 20.0% and 23.1%, respectively. There was no statistically significant change in the number of deviating measurements upon the presentation of the intervention despite the decrease in percent from 23.1% to 17.7%. The identified barriers to the intervention include clinical disagreements among radiologists. Specifically, the inter-observer variability was associated with the controversy over the choice of CT image slice (P = 0.045) and selection of start-point, axis, and end-point (P = 0.011). Clinical disagreements rather than random errors were barriers to reducing interobserver variability in CT measurement among experienced radiologists. Future interventions could aim to resolve the disagreement in an interactive approach.
| Reference Key |
woo2020interventioncurrent
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Woo, MinJae;Lowe, Steven C;Devane, A Michael;Gimbel, Ronald W; |
| Journal | current problems in diagnostic radiology |
| Year | 2020 |
| DOI |
S0363-0188(20)30013-X
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.