Nitrous oxide gas emissions estimated by liquid-phase measurements: robustness and financial opportunity in single and multi-point monitoring campaigns.

Clicks: 402
ID: 90801
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #33 of 403 articles by views in Environmental science and pollution research international

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 403 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A liquid-phase nitrous oxide sensor can be used as a proxy to estimate the gas emissions. Experiments conducted in a pilot-scale Anammox reactor, at different degrees of aeration intermittency, indicate a predictive error in the range of 13.4-19.3% during the stripping phase, with a higher error range in the unaerated phases (23.4-62.8%). The total emissions not explained by the aerated model amounted to 14.1%. Only a negligible fraction (3.6%) of the total nitrous oxide emissions were not captured by the unaerated phase model, indicating thus a minor concern for full-scale application. A sensitivity analysis performed on the present study indicates that the quality of the nitrous oxide measurement is of extreme importance to decrease the load prediction uncertainty. Air flow measurement errors have lower impact on the overall load prediction. The financial attractivity of this monitoring approach is significant in completely mixed tank reactors. In presence of a multi-point analysis, and starting from two monitoring points, the financial interest deteriorates by the relatively short lifetime of the commercially available liquid-phase nitrous oxide sensor.
Reference Key
fenu2020nitrousenvironmental Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Fenu, Alessio;Wambecq, Tom;de Gussem, Kris;Weemaes, Marjoleine;
Journal Environmental science and pollution research international
Year 2020
DOI
10.1007/s11356-019-07047-0
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.