Portable and automated fluorescence microarray biosensing platform for on-site parallel detection and early-warning of multiple pollutants.
Clicks: 361
ID: 89407
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
67.9
/100
361 views
229 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #18 of 391 articles by views in Talanta
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 391 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The portable and automated fluorescence microarray biosensing platform (FMB) that employed a compact hybrid optical structure, microfluidics, and microarray biosensors was constructed for on-site parallel detection of multiple analytes. In the FMB, a hybrid optical structure that composed of a 1 × 4 single mode fiber optic coupler, four fiber optic switches, a single-multi mode fiber optic bundle coupler was at the first time developed for the transmission of the excitation light and the collection and transmission of multi-channel fluorescence signals. Through the control of fiber optic switches, the parallel fluorescence assay of four channels could be achieved using only one excitation light and one photodiode detector on the basis of the time-resolved effect. This optical design not only greatly increased the efficiency of light transmission and fluorescence collection and detection sensitivity of the FMB, but also allows the miniaturization and portability of the whole system because of few optical separation elements used and no requirement of rigorous optical alignment. Taking Microcystin-LR (MC-LR), 2,4-D, atrazine (ATZ), and bisphenol A (BPA) for example, the application potential of the FMB to rapidly and parallelly detect four typical pollutants in real water with high sensitivity and specificity was demonstrated. The limits of detection of MC-LR, 2,4-D, ATZ, and BPA were 0.04 μg/L, 0.09 μg/L, 0.02 μg/L, and 0.03 μg/L, respectively. The FMB could also achieve early-warning of pollutants thanks to its ability of rapidity, high-frequency, and multiple-analyte detection. The FMB has significant implications as a multiplexable, portable, rapid, and quantitative detection platform for pollution accidents and water quality management to satisfy the increasing demands of alerting and protecting civilians.
| Reference Key |
long2020portabletalanta
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Long, Feng;Li, Wei;Song, Dan;Han, Xiangzhi;Zhou, Yue;Fang, Shunyan;Xu, Wenjuan;Liu, Jiayao;Zhu, Anna; |
| Journal | Talanta |
| Year | 2020 |
| DOI |
S0039-9140(19)31283-4
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.