[Formula: see text] Accelerated quantification of tissue sodium concentration in skeletal muscle tissue: quantitative capability of dictionary learning compressed sensing.

Clicks: 324
ID: 89341
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #1 of 3 articles by views in magma (new york, ny)

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
To accelerate tissue sodium concentration (TSC) quantification of skeletal muscle using Na MRI and 3D dictionary-learning compressed sensing (3D-DLCS).Simulations and in vivo Na MRI examinations of calf muscle were performed with a nominal spatial resolution of [Formula: see text]. Fully sampled and three undersampled Na MRI data sets (undersampling factors (USF) = 3, 4.4, 6.7) were evaluated. Ten healthy subjects were examined on a 3 Tesla MRI system. Results of the simulation study and the in vivo measurements were compared to the ground truth (GT) and the fully sampled fast Fourier transform (NUFFT) reconstruction, respectively.Reconstruction results of simulated data with optimized 3D-DLCS yielded a lower deviation (< 4%) from the GT than results of the NUFFT reconstruction (> 5%) and a lower standard deviation (SD). For in vivo measurements, a TSC of [Formula: see text] was observed. The mean deviation from the reference is lower for the undersampled 3D-DLCS reconstructions (3.4%) than for NUFFT reconstructions (4.6%). SD is reduced using 3D-DLCS. Compared to a fully sampled NUFFT reconstruction, acquisition time could be reduced by a factor of 4.4 while maintaining similar quantitative accuracy.The optimized 3D-DLCS reconstruction enables accelerated TSC measurements with high quantification accuracy.
Reference Key
utzschneider2020formulamagma Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Utzschneider, Matthias;Behl, Nicolas G R;Lachner, Sebastian;Gast, Lena V;Maier, Andreas;Uder, Michael;Nagel, Armin M;
Journal magma (new york, ny)
Year 2020
DOI
10.1007/s10334-019-00819-2
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.