Controlled aliasing for improved parallel imaging with a 3D spiral staircase trajectory.

Clicks: 374
ID: 89334
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #7 of 13 articles by views in Magnetic resonance in medicine

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
To introduce a modified 3D stack-of-spirals trajectory and efficient SENSE reconstruction for improved through-plane undersampling, while maintaining SNR efficiency and other benefits of spiral acquisitions.A novel spiral staircase trajectory is introduced. This trajectory is a modified stack of spirals, in which spiral arms are distributed between partitions along k . The trajectory maintains the efficient separable reconstruction with a Cartesian fast Fourier transform along the k direction, followed by a 2D slice-by-slice gridding reconstruction. An additional intermediate step introduces a phase correction to collapse the spiral arms into the prescribed slice planes. For data undersampled through plane, this produces aliasing with reduced coherence, controlled by the arm-ordering. Undersampled data can then be reconstructed with reduced g-factor using a conjugate gradient-based iterative SENSE algorithm.The trajectory significantly improves g-factor for through-plane accelerated acquisitions. Improvement manifests through both reduced overall g-factor and reduced structure in the g-factor maps. In the presented experiments, the mean g-factor decreased from 1.26 to 0.93 and the maximum g-factor decreased from 3.89 to 1.15 for R = 2 spiral staircase when compared with stack of spirals, and the mean g-factor decreased from 2.51 to 0.94 and the maximum g-factor decreased from 8.26 to 1.35 for R = 3 spiral staircase when compared with stack of spirals.The novel spiral staircase trajectory offers improved aliasing characteristics for through-plane parallel imaging acceleration in 3D spiral acquisitions.
Reference Key
anderson2020controlledmagnetic Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Magnetic resonance in medicine
Year 2020
DOI
10.1002/mrm.28154
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.