Controlled aliasing for improved parallel imaging with a 3D spiral staircase trajectory.

Clicks: 306
ID: 89334
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #8 of 13 articles by views in Magnetic resonance in medicine

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
To introduce a modified 3D stack-of-spirals trajectory and efficient SENSE reconstruction for improved through-plane undersampling, while maintaining SNR efficiency and other benefits of spiral acquisitions.A novel spiral staircase trajectory is introduced. This trajectory is a modified stack of spirals, in which spiral arms are distributed between partitions along k . The trajectory maintains the efficient separable reconstruction with a Cartesian fast Fourier transform along the k direction, followed by a 2D slice-by-slice gridding reconstruction. An additional intermediate step introduces a phase correction to collapse the spiral arms into the prescribed slice planes. For data undersampled through plane, this produces aliasing with reduced coherence, controlled by the arm-ordering. Undersampled data can then be reconstructed with reduced g-factor using a conjugate gradient-based iterative SENSE algorithm.The trajectory significantly improves g-factor for through-plane accelerated acquisitions. Improvement manifests through both reduced overall g-factor and reduced structure in the g-factor maps. In the presented experiments, the mean g-factor decreased from 1.26 to 0.93 and the maximum g-factor decreased from 3.89 to 1.15 for R = 2 spiral staircase when compared with stack of spirals, and the mean g-factor decreased from 2.51 to 0.94 and the maximum g-factor decreased from 8.26 to 1.35 for R = 3 spiral staircase when compared with stack of spirals.The novel spiral staircase trajectory offers improved aliasing characteristics for through-plane parallel imaging acceleration in 3D spiral acquisitions.
Reference Key
anderson2020controlledmagnetic Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Anderson, Ashley G;Wang, Dinghui;Pipe, James G;
Journal Magnetic resonance in medicine
Year 2020
DOI
10.1002/mrm.28154
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.