Propagation-based phase-contrast tomography of a guinea pig inner ear with cochlear implant using a model-based iterative reconstruction algorithm.
Clicks: 339
ID: 89295
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.3
/100
339 views
32 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #5 of 18 articles by views in Biomedical optics express
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Propagation-based phase-contrast computed tomography has become a valuable tool for visualization of three-dimensional biological samples, due to its high contrast between materials with similar attenuation properties. However, one of the most-widely used phase-retrieval algorithms imposes a homogeneity assumption onto the sample, which leads to artifacts for numerous applications where this assumption is violated. Prominent examples are biological samples with highly-absorbing implants. Using synchrotron radiation, we demonstrate by the example of a guinea pig inner ear with a cochlear implant electrode, how a recently developed model-based iterative algorithm for propagation-based phase-contrast computed tomography yields distinct benefits for such a task. We find that the model-based approach improves the overall image quality, removes the detrimental influence of the implant and accurately visualizes the cochlea.
| Reference Key |
hehn2018propagationbasedbiomedical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Hehn, Lorenz;Gradl, Regine;Voss, Andrej;Günther, Benedikt;Dierolf, Martin;Jud, Christoph;Willer, Konstantin;Allner, Sebastian;Hammel, Jörg U;Hessler, Roland;Morgan, Kaye S;Herzen, Julia;Hemmert, Werner;Pfeiffer, Franz; |
| Journal | Biomedical optics express |
| Year | 2018 |
| DOI |
10.1364/BOE.9.005330
|
| URL | |
| Keywords |