Transcatheter closure of elongated and pulmonary hypertensive patent arterial duct in infants using Amplatzer vascular plug II.
Clicks: 311
ID: 88951
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
75.6
/100
311 views
216 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #6 of 10 articles by views in Cardiology in the Young
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
To evaluate the feasibility, efficacy, and safety of Amplatzer vascular plug II in large and elongated ducts in infants.Patent arterial duct device closure is technically challenging in infants with large and elongated ducts because Amplatzer duct occluder and Amplatzer duct occluder II have high chances of causing aortic coarctation and left pulmonary artery stenosis, respectively. The Amplatzer vascular plug II being soft with no retention discs on either sides helps in mitigating these problems.This is a prospective, observational study involving infants with clinical, echocardiographic and angiographic evidence of large left to right shunt. All the children underwent duct closure using Amplatzer vascular plug II.Eighteen infants qualified for the study. Mean age and weight were 8.63 ± 3.84 months and 6.3 ± 1.7 kg, respectively. The angiographic mean duct diameter at the pulmonary artery end was 4.66 ± 0.92 mm, and the mean duct length was 9.4 ± 2.48 mm. The size of Amplatzer vascular plug II used varied from 6 mm to 10 mm. Technical success was achieved in 16/18 cases. One patient had device embolisation, and in the other, the device was found to be unstable. The ratio of Amplatzer vascular plug II size to the duct diameter was 1.65 ± 0.27, while the ratio of ductal length to device length was 1.48 ± 0.46 in those with successful outcome.Amplatzer vascular plug II is a safe and effective option in appropriately selected infants with elongated ducts. Diameter and length of Amplatzer vascular plug II vis-a-vis those of the ductus are important determinants of the successful outcome.
| Reference Key |
jain2020transcathetercardiology
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Jain, Sneha M;Pradhan, Priya M;Sen, Supratim;Dalvi, Bharat V; |
| Journal | Cardiology in the Young |
| Year | 2020 |
| DOI |