Fluorescent immunoliposomal nanovesicles for rapid multi-well immuno-biosensing of histamine in fish samples.
Clicks: 328
ID: 88799
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
328 views
34 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #106 of 409 articles by views in Chemosphere
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 409 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Scombroid poisoning in fish-based and other food products has raised concerns due to toxicity outbreaks and incidences associated with histamine, thus measuring the amount of histamine toxic molecule is considered crucial quality indicator of food safety and human health. In this study, liposome-based measurement of histamine was performed via rupturing mechanism of sulforhodamine B dye encapsulated anti-histamine antibody conjugated liposomal nanovesicles. The immunosensing ability of immuno-liposomal format was assessed by monitoring the fluorescence at excitation/emission wavelength of 550/585 nm. Immuno-liposomal format assays were considered, one based on single wash procedure (Method 1), which had a detection limit of 10 ppb and quantification limit 15-80 ppb. While Method 2 based on one-by-one wash procedure had a detection limit of 2-3 ppb and quantification limit 8.5 ppb-200 ppm that required 2 h 30 min to perform. In view of better quantification limit, Method 2 was chosen for further tests required to validate its applicability in real samples. The feasibility of Method 2 was reconfirmed in fresh mackerel fish, and canned fish (tuna and salmon) with a similar detection limits but with low amplified fluorescence signals and sufficient levels of histamine recovery from fresh mackerel (73.50-99.98%), canned tuna (79.08-103.74%) and salmon (74.56-99.02%). The specificity and method accuracy were expressed as % CV in the range 5.34%-8.48%. Overall, the developed multi-well sensing system (Method 2) showed satisfactory specificity, cost effectiveness, rapidity, and stability for monitoring histamine toxicity as a practical food diagnostic device.
| Reference Key |
bajpai2020fluorescentchemosphere
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Bajpai, Vivek K;Oh, CheolWoo;Khan, Imran;Haldorai, Yuvaraj;Gandhi, Sonu;Lee, Hoomin;Song, Xinjie;Kim, Myunghee;Upadhyay, Ashutosh;Chen, Lei;Huh, Yun Suk;Han, Young-Kyu;Shukla, Shruti; |
| Journal | Chemosphere |
| Year | 2020 |
| DOI |
S0045-6535(19)32644-X
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.