Implementation of machine learning into clinical breast MRI: Potential for objective and accurate decision-making in suspicious breast masses.

Clicks: 271
ID: 88255
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #1,155 of 2,056 articles by views in PloS one

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 2,056 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
We investigated whether the integration of machine learning (ML) into MRI interpretation can provide accurate decision rules for the management of suspicious breast masses. A total of 173 consecutive patients with suspicious breast masses upon complementary assessment (BI-RADS IV/V: n = 100/76) received standardized breast MRI prior to histological verification. MRI findings were independently assessed by two observers (R1/R2: 5 years of experience/no experience in breast MRI) using six (semi-)quantitative imaging parameters. Interobserver variability was studied by ICC (intraclass correlation coefficient). A polynomial kernel function support vector machine was trained to differentiate between benign and malignant lesions based on the six imaging parameters and patient age. Ten-fold cross-validation was applied to prevent overfitting. Overall diagnostic accuracy and decision rules (rule-out criteria) to accurately exclude malignancy were evaluated. Results were integrated into a web application and published online. Malignant lesions were present in 107 patients (60.8%). Imaging features showed excellent interobserver variability (ICC: 0.81-0.98) with variable diagnostic accuracy (AUC: 0.65-0.82). Overall performance of the ML algorithm was high (AUC = 90.1%; BI-RADS IV: AUC = 91.6%). The ML algorithm provided decision rules to accurately rule-out malignancy with a false negative rate <1% in 31.3% of the BI-RADS IV cases. Thus, integration of ML into MRI interpretation can provide objective and accurate decision rules for the management of suspicious breast masses, and could help to reduce the number of potentially unnecessary biopsies.
Reference Key
ellmann2020implementationplos Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Ellmann, Stephan;Wenkel, Evelyn;Dietzel, Matthias;Bielowski, Christian;Vesal, Sulaiman;Maier, Andreas;Hammon, Matthias;Janka, Rolf;Fasching, Peter A;Beckmann, Matthias W;Schulz Wendtland, Rüdiger;Uder, Michael;Bäuerle, Tobias;
Journal PloS one
Year 2020
DOI
10.1371/journal.pone.0228446
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.