The Bacteriological Quality of Drinking Water of Water Coolers Located in Some hospitals in Rasht
Clicks: 492
ID: 87423
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
71.1
/100
492 views
355 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 3 articles by views in caspian journal of health research
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Objectives: Research background and objective: Having access to safe drinking water has an essential role in ensuring public health. Ignoring damages caused by failures in water distribution system leads to water contamination. This study intended to investigate the bacteriological quality of drinking water of water coolers in four hospitals of Razi, Heshmat, Al-Zahra and Aria in Rasht Township.
Methods: In order to meet the objective of the study, 13 water coolers located in these hospitals were randomly selected. The values of total coliforms, heterotrophic bacteria, residual chlorine, pH, and turbidity were measured. The data were analyzed using Excel and SPSS.
Results: The findings showed a strong relationship existed between pH values of input and output water (R=0.55), but that for turbidity was insignificant (R=0.13) (p=0.42). In two cases, coliform bacteria were observed, too. The value of HPC in tested samples was less than 15 cfu/ml before entering and after leaving water coolers.
Conclusion The results indicated absence of coliform bacteria. The reduction of residual chlorine after the water filtration system in water coolers indicated low-level of contamination in water coolers. Therefore, regular servicing and monitoring water coolers and their connections would ensure health of staff members, patients and all who enter hospitals.
| Reference Key |
naghipour2016thecaspian
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Naghipour, Dariush;Dodangeh, Fatemeh;Mehrabian, Fardin;Ebrahim-Nezhad, Elahe;Rouhbakhsh, Esmaeel; |
| Journal | caspian journal of health research |
| Year | 2016 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.