Removal of Hydrogen Sulfide in Septic Tanks for Treating Black Water via an Immobilized Media of Sulfur-Oxidizing Bacteria.
Clicks: 289
ID: 87274
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
289 views
47 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #448 of 862 articles by views in International journal of environmental research and public health
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 862 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In South Korea, the installation of septic tanks for treating black water (STBW) is regulated even in sewage treatment areas to prevent the black water deposition in combined sewers. STBWs in which black water is anaerobically decomposed generate high concentrations of hydrogen sulfide (HS). In this study, an immobilized media of sulfur-oxidizing bacteria (SOB) was used to remove the HS. SOB media was prepared by using activated sludge collected from a wastewater treatment plant. Prior to field application, an appropriate cultivation period and aeration rate for SOB activation were estimated through a laboratory-scale test. The SOB was activated after a 23-day cultivation period and an aeration rate of 0.25 L-water/L-air/min. Moreover, the maximum HS removal efficiency was observed at a cultivation period of 43 days and an aeration rate of 0.38 L-water/L-air/min. Then, the SOB media was installed on STBWs of various capacities. The HS removal efficiency was compared between with and without SOB media. The maximum HS elimination capacity with SOB media was 12.3 g/m/h, which was approximately three times higher than without SOB media. Furthermore, the energy efficiency and oxidation rate were also three times higher with SOB, demonstrating the applicability of SOB for HS removal in STBW.
| Reference Key |
kang2020removalinternational
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Kang, Jeong-Hee;Namgung, Hyeong-Gyu;Cho, Jeong-Il;Yoo, Sung Soo;Lee, Bong-Jae;Ji, Houn Wook; |
| Journal | International journal of environmental research and public health |
| Year | 2020 |
| DOI |
E684
|
| URL | |
| Keywords |
Citations