Application of vapor phase corrosion inhibitors for contaminated environments

Clicks: 234
ID: 87150
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #53 of 271 articles by views in e3s web of conferences

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 271 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Availability and accessibility to clean water for industrial applications such as hydrotesting and hydrostatic testing of pipelines, vessels, and plumbing distribution systems has been a challenging task especially when the job sites are in remote locations. When contaminated water is used in these tests, corrosion of the metallic components of the systems, during and after testing become a major concern. Vapor-phase corrosion inhibitors (VCI), can be added to water in small concentrations to prevent corrosion during testing, during wet storage and after testing. These inhibitors are to prevent corrosion of metallic components in three phases, within the solution, at the water line, and above the water line. Three commercially available corrosion inhibitors were evaluated in this investigation. Laboratory studies are presented in this paper, showed the effectiveness of VCI products in both fresh and salt water applications. Average corrosion rate dropped from ~10 mpy for salt solution to less than 1-1.6 mpy when various inhibitors was added. The effectiveness of these inhibitors is remarkable in the fresh water (less than 0.4 mpy). Exposure of the steel samples to these inhibitors did not show any loss in mechanical properties. Both strength and ductility of the low carbon steel samples was maintained.
Reference Key
behzad2019applicatione3s Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Behzad, Bavarian;B., Avanessian Aline;Reza, Yekani;Lisa, Reiner;Ivana, Radic Borsic;Boris, Miksic;
Journal e3s web of conferences
Year 2019
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.