Removing arsenic and co-occurring contaminants from drinking water by full-scale ion exchange and point-of-use/point-of-entry reverse osmosis systems.
Clicks: 368
ID: 87066
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
64.0
/100
368 views
219 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #23 of 168 articles by views in Water research
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 168 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This study investigated the performance of two full-scale ion exchange (IX) systems, one point-of-entry (POE) reverse osmosis (RO) system and nine point-of-use (POU) RO units for simultaneous removal of arsenic and several co-occurring contaminants from drinking water. The study was performed as part of the U.S. Environmental Protection Agency's Arsenic Treatment Demonstration Program. The IX systems, with strong base anionic (SBA) resins, effectively removed arsenic (As), nitrate (NO) and uranium (U) to below respective maximum contaminant levels and vanadium (V) and molybdenum (Mo) to below 2 μg/L. The useful run length, as determined by either 10-mg/L (as N) nitrate or 10-μg/L arsenic breakthrough, was approximately 400 bed volumes (BV) initially. However, it was decreased over time, e.g., by 15% in 13 months at one site and 33% in 7 months at another site, apparently caused by resin fouling due to the presence of 2-mg/L natural organic matter (NOM) in source waters. The use of dual resins ‒ an acrylic SBA resin underlain by a polystyrene SBA resin ‒ effectively removed NOM and allowed the system to perform at its baseline level through the 13-month study. Arsenic and nitrate peaking occurred when the resins were not regenerated timely. The removal of contaminants appeared to follow a selectivity sequence: U, Mo > V > SO > HAsO > NO > HCO. RO effectively removed arsenic, nitrate, antimony, uranium and vanadium, mostly with a >99% rejection rate. The POE RO coupled with dual plumbing (only treating a fraction of water for potable use) and POU RO in individual homes could be used as low-cost alternatives to traditional RO treatment.
| Reference Key |
chen2019removingwater
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Chen, Abraham S C;Wang, Lili;Sorg, Thomas J;Lytle, Darren A; |
| Journal | Water research |
| Year | 2019 |
| DOI |
S0043-1354(19)31232-1
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.