Source water characteristics and building-specific factors influence corrosion and point of use water quality in a decentralized Arctic drinking water system.
Clicks: 247
ID: 87064
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
247 views
55 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #76 of 112 articles by views in Environmental science & technology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Access to clean and safe drinking water is a perpetual concern in Arctic communities due to challenging climatic conditions, limited options for the transportation of equipment and process chemicals, and the ongoing effects of colonialism. Water samples were gathered from multiple locations in a decentralized trucked drinking water system in Nunavut, Canada, over the course of one year. The results indicate that point of use drinking water quality was impacted by conditions in the source water and in individual buildings and strongly suggest that lead and copper measured at the tap were related to corrosion of onsite premises plumbing components. Humic-like substances were the dominant organic fraction in all samples, as determined by regional integration of fluorescence data. Iron and manganese levels in the source water and throughout the water system were higher in the winter and lower in the summer months. Elevated concentrations of copper (>2000 µg L-1) and lead (>5 µg L-1) were detected in tap water from some buildings. Field flow fractionation coupled with an ICP-MS and a UV-Vis spectrometer was used to demonstrate the link between source water characteristics (high organics, iron, manganese) and lead and copper in point of use drinking water.
| Reference Key |
gora2020sourceenvironmental
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Gora, Stephanie;Trueman, Benjamin F;Soucie, Tim Anaviapik;Gavin, Megan Kunuk;Ontiveros, C Carolina;Campbell, Jessica;L'Herault, Vincent;Stoddart, Amina K;Gagnon, Graham A; |
| Journal | Environmental science & technology |
| Year | 2020 |
| DOI |
10.1021/acs.est.9b04691
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.