Single-Mode Tapered Vertical SU-8 Waveguide Fabricated by E-Beam Lithography for Analyte Sensing
Clicks: 242
ID: 86769
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
242 views
24 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1,015 of 1,694 articles by views in sensors
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In this paper, we propose a novel vertical SU-8 waveguide for evanescent analyte sensing. The waveguide is designed to possess a vertical and narrow structure to generate evanescent waves on both sides of the waveguide’s surface, aimed at increasing the sensitivity by enlarging the sensing areas. We performed simulations to monitor the influence of different parameters on the waveguide’s performance, including its height and width. E-beam lithography was used to fabricate the structure, as this one-step direct writing process enables easy, fast, and high-resolution fabrication. Furthermore, it reduces the sidewall roughness and decreases the induced scattering loss, which is a major source of waveguide loss. Couplers were added to improve the coupling efficiency and alignment tolerance, and will contribute to the feasibility of a plug-and-play optical system. Optical measurements show that the transmission loss is 1.03 ± 0.19 dB/cm. The absorption sensitivity was measured to be 4.8 dB per refractive index unit (dB/RIU) for saline solutions with various concentrations.
| Reference Key |
xin2019singlemodesensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Xin, Yu;Pandraud, Gregory;Zhang, Yongmeng;French, Paddy; |
| Journal | sensors |
| Year | 2019 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments