Orientation of the round window membrane: A normative study of inner ear anatomical orientation using 2D projections of 3D volumes.
Clicks: 421
ID: 86236
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
421 views
68 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #6 of 14 articles by views in anatomical record (hoboken, nj : 2007)
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Orientation of the Round Window Membrane (RWM) is an important metric to establish if utilized as a potential access for targeted delivery of magnetically guided nanomedicines to the inner ear. Orientation with respect to an internal reference frame (such as the planes defined by the semicircular-canals [SCC]) may provide an internally consistent basis if the basis is orthogonal and consistent (from patient to patient).Utilizing a micro computed tomography (CT), 20 temporal bones are scanned for anatomical information. The scanned data sets are loaded into an imaging program to provide volumetric reconstruction and segmentation. Volumetric models of the anatomical relationships between the inner ear SCC and the RWM are utilized to get normative projection angle information and are statistically analyzed.Micro-CT shows low to moderate reliability for reproducibility, intraobserver, and interobserver measurements; in addition, it provides mean values (±SD) for the various measured angles. The combined mean angular values for surface orientation of the RWM, with respect to the SCC basis (quasi-orthogonal spherical coordinate system), was 57.0° ± 20.9°as measured from the line defining the posterior SCC plane in the direction of the line defining the superior SCC plane. An angle of 65.2° ± 19.1° was measured for an angle away from the line defining the horizontal SCC plane.
| Reference Key |
rutel2019orientationanatomical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Rutel, Isaac B;Stoner, Julie;Kota, Pravina;Dormer, Kenneth;Alleman, Anthony; |
| Journal | anatomical record (hoboken, nj : 2007) |
| Year | 2019 |
| DOI |
10.1002/ar.24327
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.