A Novel Evaluation Model for a Mixed-Reality Surgical Navigation System: Where Microsoft HoloLens Meets the Operating Room.

Clicks: 356
ID: 85778
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #2 of 4 articles by views in surgical innovation

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
HoloLens-based mixed-reality surgical navigation system (MR-SNS) technology has made great progress. However, the methodology for evaluating users' perceptions concerning the safety, comfort, and efficiency of MR-SNS is still in its infancy. This study was intended to develop a method to systematically evaluate an existing MR-SNS system during actual clinical applications. This method differs from other existing methods currently used in industry, education, and device maintenance. Based on analytical hierarchy process theory and ergonomics evaluation methods, in this article, we propose a novel multicriteria evaluation model for a HoloLens-based MR-SNS. The model includes factors such as comfort, safety, and effectiveness, and is performed in an actual clinical application. A comprehensive experimental platform and scoring system that can analyze all indicators was built. The validation test showed no statistically significant differences in the accuracy of the 3 different movement patterns ( = .95, > .05). However, the static pattern showed the best accuracy. In addition, no significant difference ( = .68, > .05) in accuracy was found under 4 kinds of illuminance. A comparison of the results of this evaluation model and the input from experts who use the HoloLens-based MR-SNS in hospitals, indicated that this model has good precision (100%), recall (80%), and F1-measure (88.89%). The results highlighted the full efficacy of the proposed model in determining whether this system can be used in clinical trials to provide indicators for preliminary ex ante feasibility studies. This article describes the lessons learned from conducting this evaluation study of MR-SNS as part of the design process.
Reference Key
zuo2020asurgical Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Zuo, Yan;Jiang, Taoran;Dou, Jiansheng;Yu, Dewang;Ndaro, Zaphlene Nyakuru;Du, Yunxiao;Li, Qingfeng;Wang, Shuyi;Huang, Gang;
Journal surgical innovation
Year 2020
DOI
10.1177/1553350619893236
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.