Preparation of a chemically stable metal-organic framework and multi-walled carbon nanotube composite as a high-performance electrocatalyst for the detection of lead.
Clicks: 307
ID: 85494
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
307 views
38 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #20 of 50 articles by views in The Analyst
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The fabrication of chemically stable metal-organic frameworks for electrochemical sensors is essential to broaden their applications. In this study, the integration of a Zr-based metal-organic framework (UiO-66-NH2) with multi-walled carbon nanotubes (MWCNTs) was achieved by a one-pot solvothermal reaction. This composite was then characterized by scanning electron microscopy, transmission electron microscopy, powder X-ray diffraction, Fourier transform infrared spectroscopy, and contact angle measurements. The porous structure and unreacted amine groups provided by UiO-66-NH2 frameworks accompanied by the excellent conductivity of MWCNTs have made this composite an ideal electrode material for lead detection. After the optimization of MWCNT content and the detection conditions, the oxidation peak currents were proportional to lead concentrations in the range of 0.001-0.8 μmol L-1 with a low detection limit of 0.5 nmol L-1 (S/N = 3). More importantly, the well-preserved crystallinity of MWCNTs@UiO-66-NH2 after 80 cycles and after being soaked in different pH aqueous solutions indicates the promising application of this sensor for real samples. Satisfactory recoveries were achieved when this sensor was used to detect lead in real samples. Furthermore, the excellent stability of this composite makes it possible to be employed in other fields, including extreme acidic media.
| Reference Key |
sun2020preparationthe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Sun, Xin;Chen, Yuling;Xie, Yao;Wang, Lu;Wang, Yang;Hu, Xiaoya; |
| Journal | The Analyst |
| Year | 2020 |
| DOI |
10.1039/c9an02299f
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.