Reliable estimation of brain intravoxel incoherent motion parameters using denoised diffusion-weighted MRI.
Clicks: 317
ID: 85413
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
73.2
/100
317 views
234 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #4 of 9 articles by views in NMR in biomedicine
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In this study, we evaluate whether diffusion-weighted magnetic resonance imaging (DW-MRI) data after denoising can provide a reliable estimation of brain intravoxel incoherent motion (IVIM) perfusion parameters. Brain DW-MRI was performed in five healthy volunteers on a 3 T clinical scanner with 12 different b-values ranging from 0 to 1000 s/mm . DW-MRI data denoised using the proposed method were fitted with a biexponential model to extract perfusion fraction (PF), diffusion coefficient (D) and pseudo-diffusion coefficient (D*). To further evaluate the accuracy and precision of parameter estimation, IVIM parametric images obtained from one volunteer were used to resimulate the DW-MRI data using the biexponential model with the same b-values. Rician noise was added to generate DW-MRI data with various signal-to-noise ratio (SNR) levels. The experimental results showed that the denoised DW-MRI data yielded precise estimates for all IVIM parameters. We also found that IVIM parameters were significantly different between gray matter and white matter (P < 0.05), except for D* (P = 0.6). Our simulation results show that the proposed image denoising method displays good performance in estimating IVIM parameters (both bias and coefficient of variation were <12% for PF, D and D*) in the presence of different levels of simulated Rician noise (SNR = 20-40). Simulations and experiments show that brain DW-MRI data after denoising can provide a reliable estimation of IVIM parameters.
| Reference Key |
huang2020reliablenmr
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Huang, Hsuan-Ming; |
| Journal | NMR in biomedicine |
| Year | 2020 |
| DOI |
10.1002/nbm.4249
|
| URL | |