Reliable estimation of brain intravoxel incoherent motion parameters using denoised diffusion-weighted MRI.

Clicks: 372
ID: 85413
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #4 of 9 articles by views in NMR in biomedicine

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
In this study, we evaluate whether diffusion-weighted magnetic resonance imaging (DW-MRI) data after denoising can provide a reliable estimation of brain intravoxel incoherent motion (IVIM) perfusion parameters. Brain DW-MRI was performed in five healthy volunteers on a 3 T clinical scanner with 12 different b-values ranging from 0 to 1000 s/mm . DW-MRI data denoised using the proposed method were fitted with a biexponential model to extract perfusion fraction (PF), diffusion coefficient (D) and pseudo-diffusion coefficient (D*). To further evaluate the accuracy and precision of parameter estimation, IVIM parametric images obtained from one volunteer were used to resimulate the DW-MRI data using the biexponential model with the same b-values. Rician noise was added to generate DW-MRI data with various signal-to-noise ratio (SNR) levels. The experimental results showed that the denoised DW-MRI data yielded precise estimates for all IVIM parameters. We also found that IVIM parameters were significantly different between gray matter and white matter (P < 0.05), except for D* (P = 0.6). Our simulation results show that the proposed image denoising method displays good performance in estimating IVIM parameters (both bias and coefficient of variation were <12% for PF, D and D*) in the presence of different levels of simulated Rician noise (SNR = 20-40). Simulations and experiments show that brain DW-MRI data after denoising can provide a reliable estimation of IVIM parameters.
Reference Key
huang2020reliablenmr Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal NMR in biomedicine
Year 2020
DOI
10.1002/nbm.4249
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.