BIGDOSE: software for 3D personalized targeted radionuclide therapy dosimetry.
Clicks: 267
ID: 84605
2020
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Steady Performance
65.7
/100
263 views
216 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
Advance 3D quantitative radionuclide imaging techniques boost the accuracy of targeted radionuclide therapy (TRT) dosimetry to voxel level. The goal of this work is to develop a comprehensive 3D dosimetric software, BIGDOSE, with new features of image registration and virtual CT for patient-specific dosimetry.BIGDOSE includes a portable graphical user interface written in Python, integrating (I) input of sequential ECT/CT images; (II) segmentation; (III) non-rigid image registration; (IV) curve fitting and voxel-based integration; (V) dose conversion and (VI) 3D dose analysis. The accuracy of the software was evaluated using a simulation study with 9 XCAT phantoms. We simulated SPECT/CT acquisitions at 1, 12, 24, 72 and 144-hrs post In-111 Zevalin injection with inter-scans misalignments using an analytical projector for medium energy general purpose (MEGP) collimator, modeling attenuation, scatter and collimator-detector response. The SPECT data were reconstructed using quantitative OS-EM method. A CT organ-based registration was performed before the dose calculation. Organ absorbed doses for the corresponding Y-90 therapeutic agent were calculated on target organs and compared with those obtained from OLINDA/EXM, using dose measured from GATE as the gold standard. One patient with In-111 DTPAOC injection as well as two patients with Y-90 microsphere embolization were used to demonstrate the clinical effectiveness of our software.In the simulation, the organ dose errors of BIGDOSE were -9.59%±9.06%, -8.36±5.82%, -23.41%±6.67%, -6.05%±2.06% for liver, spleen, kidneys and lungs, while they were -25.72%±12.52%, -14.93%±10.91%, -28.63%±12.97% and -45.30%±5.84% for OLINDA/EXM. Cumulative dose volume histograms, dose maps and iso-dose contours provided 3D dose distribution information on the simulated and patient data.BIGDOSE provides a one-stop platform for voxel-based dose estimation with enhanced functions. It is a promising tool to streamline the current clinical TRT dosimetric practice with high accuracy, incorporating 3D personalized imaging information for improved treatment outcome.
Abstract Quality Issue:
This abstract appears to be incomplete or contains metadata (291 words).
Try re-searching for a better abstract.
| Reference Key |
li2020bigdosequantitative
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Li, Tiantian;Zhu, Licheng;Lu, Zhonglin;Song, Na;Lin, Ko-Han;Mok, Greta S P; |
| Journal | Quantitative imaging in medicine and surgery |
| Year | 2020 |
| DOI |
10.21037/qims.2019.10.09
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.