Characterization and analytical validation of a new antigenic rapid diagnostic test for Ebola virus disease detection.
Clicks: 221
ID: 83994
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
221 views
39 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #74 of 102 articles by views in plos neglected tropical diseases
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Hemorrhagic fever outbreaks are difficult to diagnose and control in part because of a lack of low-cost and easily accessible diagnostic structures in countries where etiologic agents are present. Furthermore, initial clinical symptoms are common and shared with other endemic diseases such as malaria or typhoid fever. Current molecular diagnostic methods such as polymerase chain reaction require trained personnel and laboratory infrastructure, hindering diagnostics at the point of need, particularly in outbreak settings. Therefore, rapid diagnostic tests such as lateral flow can be broadly deployed and are typically well-suited to rapidly diagnose hemorrhagic fever viruses, such as Ebola virus. Early detection and control of Ebola outbreaks require simple, easy-to-use assays that can detect very low amount of virus in blood. Here, we developed and characterized an immunoassay test based on immunochromatography coupled to silver amplification technology to detect the secreted glycoprotein of EBOV. The glycoprotein is among the first viral proteins to be detected in blood. This strategy aims at identifying infected patients early following onset of symptoms by detecting low amount of sGP protein in blood samples. The limit of detection achieved by this sGP-targeted kit is 2.2 x 104 genome copies/ml in plasma as assayed in a monkey analytical cohort. Clinical performance evaluation showed a specificity of 100% and a sensitivity of 85.7% when evaluated with plasma samples from healthy controls and patients infected with Zaire Ebola virus from Macenta, Guinea. This rapid and accurate diagnostic test could therefore be used in endemic countries for early detection of infected individuals in point of care settings. Moreover, it could also support efficient clinical triage in hospitals or clinical centers and thus reducing transmission rates to prevent and better manage future severe outbreaks.
| Reference Key |
couturier2020characterizationplos
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Couturier, Céline;Wada, Atsuhiko;Louis, Karen;Mistretta, Maxime;Beitz, Benoit;Povogui, Moriba;Ripaux, Maryline;Mignon, Charlotte;Werle, Bettina;Lugari, Adrien;Pannetier, Delphine;Godard, Sabine;Bocquin, Anne;Mely, Stéphane;Béavogui, Ismaël;Hébélamou, Jean;Leuenberger, David;Leissner, Philippe;Yamamoto, Takeshi;Lécine, Patrick;Védrine, Christophe;Chaix, Julie; |
| Journal | plos neglected tropical diseases |
| Year | 2020 |
| DOI |
10.1371/journal.pntd.0007965
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.