Identification of malignant early repolarization pattern by late QRS activity in high-resolution magnetocardiography.

Clicks: 360
ID: 83955
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #2 of 3 articles by views in annals of noninvasive electrocardiology : the official journal of the international society for holter and noninvasive electrocardiology, inc

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The early repolarization pattern (ERP) in electrocardiography (ECG) has been considered as a risk for ventricular fibrillation (VF), but effective methods for identification of malignant ERP are still required. We investigated whether high spatiotemporal resolution 64-channel magnetocardiography (MCG) would enable distinction between benign and malignant ERPs.Among all 2,636 subjects who received MCG in our facility, we identified 116 subjects (43 ± 18 years old, 54% male) with inferior and/or lateral ERP in ECG and without structural heart disease, including 13 survivors of VF (ERP-VF(+)) and 103 with no history of VF (ERP-VF(-)). We measured the following MCG parameters in a time-domain waveform of relative current magnitude: (a) QRS duration (MCG-QRSD), (b) root-mean-square of the last 40 ms (MCG-RMS40), and (c) low amplitude (<10% of maximal) signal duration (MCG-LAS).Compared to ERP-VF(-), ERP-VF(+) subjects presented a significantly longer MCG-QRS (108 ± 24 vs. 91 ± 23 ms, p = .02) and lower MCG-RMS40 (0.10 ± 0.08 vs. 0.25 ± 0.20, p = .01) but no difference in MCG-LAS (38 ± 22 vs. 29 ± 23 ms, p = .17). MCG-QRSD and MCG-RMS40 showed significantly larger area under the ROC curve compared to J-peak amplitude in ECG (0.72 and 0.71 vs. 0.50; p = .04 and 0.03). The sensitivity, specificity, and odds ratio for identifying VF(+) based on MCG-QRSD ≥ 100 ms and MCG-RMS40 ≤ 0.24 were 69%, 74%, and 6.33 (95% CI, 1.80-22.3), and 92%, 48%, and 10.9 (95% CI, 1.37-86.8), respectively.Magnetocardiography is an effective tool to distinguish malignant and benign ERPs.
Reference Key
iwakami2020identificationannals Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Iwakami, Naotsugu;Aiba, Takeshi;Kamakura, Shiro;Takaki, Hiroshi;Furukawa, Toshiaki A;Sato, Tosiya;Sun, Wenxu;Shishido, Toshiaki;Nishimura, Kunihiro;Yamada-Inoue, Yuko;Nagase, Satoshi;Shimizu, Wataru;Yasuda, Satoshi;Sugimachi, Masaru;Kusano, Kengo;
Journal annals of noninvasive electrocardiology : the official journal of the international society for holter and noninvasive electrocardiology, inc
Year 2020
DOI
10.1111/anec.12741
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.