Determination of the lanthanides, uranium and plutonium by means of on-line high-pressure ion chromatography coupled with sector field inductively coupled plasma-mass spectrometry to characterize nuclear samples.
Clicks: 357
ID: 83288
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
357 views
23 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #12 of 58 articles by views in journal of chromatography a
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
High-pressure ion chromatography (HPIC) was coupled with sector field inductively coupled plasma-mass spectrometry (SF-ICP-MS) to separate plutonium (Pu), uranium (U), neodymium (Nd) and gadolinium (Gd) nuclides from isobaric nuclides and to quantify them with high sensitivity. In this study, mixed bed ion exchange columns CG5A and CS5A were used, from which Pu and U were eluted first using 1 M nitric acid. The lanthanides were then separated using a gradient of 0.1-0.15 M oxalic acid with the pH adjusted to 4.5. The HPIC-SF-ICP-MS method was validated using different sample matrices, i.e. spent nuclear fuel and soil. The method was found to be repeatable and gave rise to transient signals suitable for quantification of nuclide-specific concentrations using external calibration. In terms of accuracy, the HPIC-SF-ICP-MS measurement results were in good agreement with those obtained using thermal ionization mass spectrometry (TIMS). Finally, the method provides an improvement in sample throughput (≤60 minutes per sample) and reduces exposure of the operator to radiation compared to off-line gravitational chromatography followed by TIMS.
| Reference Key |
wanna2019determinationjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Wanna, Nancy Nazem;Van Hoecke, Karen;Dobney, Andrew;Vasile, Mirela;Cardinaels, Thomas;Vanhaecke, Frank; |
| Journal | journal of chromatography a |
| Year | 2019 |
| DOI |
S0021-9673(19)31310-X
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.