Near-Infrared Lanthanide-Doped Nanoparticles for a Low Interference Lateral Flow Immunoassay Test.

Clicks: 332
ID: 83029
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #113 of 899 articles by views in ACS applied materials & interfaces

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 899 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The lateral flow immunoassay test (LFT), as a method of a point of care test, is widely used in disease diagnosis, food security, and environment observation due to its portability and testing rapidity. A fluorescence lateral flow immunoassay was developed recently to enhance the sensitivity and accuracy of the LFT. However, for most fluorescence reporters, their emission and excitation wavelengths are located in the ultraviolet or visible region. Serum or whole blood significantly absorbs and scatters light of this region, and this will result in background signal interference. In this study, we replace traditional fluorescence reporters with near-infrared lanthanide-doped nanoparticles (NIR-RENPs) to establish a NIR-LFT platform. Blood and other biological samples scatter and absorb less near-infrared light than visible light, and the autofluorescence of biological samples is rarely located in this region. Therefore, using NIR light as a signal can diminish the interference of background noise and suffer from less signal attenuation. In addition, compared with commonly used NIR organic dye, NIR-RENPs have better stability. It is promising that lateral flow immunoassays based on NIR lanthanide-doped nanoparticles are able to acquire a lower detection limit and better accuracy, and they are more suitable for application in commercial settings.
Reference Key
liu2020nearinfraredacs Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Liu, Qingyun;Cheng, Shengming;Chen, Rui;Ke, Jiaming;Liu, Yawei;Li, Yongfang;Feng, Wei;Li, Fuyou;
Journal ACS applied materials & interfaces
Year 2020
DOI
10.1021/acsami.9b22449
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.