The cotton test redistributes nasal airflow in patients with empty nose syndrome.
Clicks: 339
ID: 82249
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
74.9
/100
339 views
223 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #4 of 4 articles by views in international forum of allergy & rhinology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Empty nose syndrome (ENS) remains a controversial disease primarily associated with inferior turbinate tissue loss. Cotton placement into the inferior meatus often alleviates ENS symptoms within minutes, but the physiologic explanation for this phenomenon is unknown. Computational fluid dynamics (CFD) was employed to evaluate the mechanisms of altered nasal airflow conferred by cotton testing.Six ENS patients (12 sides) with pre-existing sinus computed tomography (CT) imaging were enrolled after marked symptomatic improvement (decrease in score on the Empty Nose Syndrome 6-Item Questionnaire [ENS6Q] of >7 points) with office-based cotton testing. The fashioned cotton plug was labeled in situ with iohexol contrast spray, and sinus CT was immediately obtained to detect cotton contouring in the inferior meatus. CT imaging from pre- and post-cotton placement was analyzed using comparative CFD techniques.After cotton placement, significant symptomatic improvement and reduced ENS6Q scores (16.8 ± 4.1 to 3.1 ± 2.4; p < 0.001) were recorded. Using CFD, cotton placement produced an expected 21% increase in upper airway resistance (p < 0.05). However, a significant shift in the nasal airflow distribution was also detected, with a transition of airflow vectors away from a middle meatus jetstream (-41%; p < 0.002).Objective CFD assessment confirmed that the cotton test not only increases nasal resistance, but also restores airflow distribution to the inferior meatus in symptomatic ENS patients. These results highlight the potential efficacy of cotton test in ENS patients and further bolster the utility of this tool in identifying appropriate candidates for the inferior meatus augmentation procedure.
| Reference Key |
malik2020theinternational
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Malik, Jennifer;Thamboo, Andrew;Dholakia, Sachi;Borchard, Nicole A;McGhee, Sam;Li, Chengyu;Zhao, Kai;Nayak, Jayakar V; |
| Journal | international forum of allergy & rhinology |
| Year | 2020 |
| DOI |
10.1002/alr.22489
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.