Penetration Profiles of a Class IV Therapeutic Laser and a Photobiomodulation Therapy Device in Equine Skin.
Clicks: 333
ID: 82071
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
65.7
/100
333 views
201 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #3 of 7 articles by views in journal of equine veterinary science
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Photobiomodulation therapy (PBMT) effects depend on the energy settings and laser penetration. We investigated the penetration time profiles of two different light therapy devices, at the dark and light skin regions in horses. Six light skin and six dark skin adult clinically healthy Arab and Quarter horses were used. A cutometer was used to measure the width of the skin fold from both sides of the cervical area, followed by three measurements of the thickness of the same skin fold by transversal and longitudinal ultrasonography (US). The depth of light penetration was compared based on the percentage of penetration versus power, between a portable PBMT device versus a class IV laser device. The laser mean power output was measured with an optical power meter system for 120 seconds after penetrating the skin. Skin width and laser penetration were compared among equipment by paired "t" test. There was no difference in the width of the skin fold between measurements acquired by the cutometer against either longitudinal or transversal US or between the US measurements at cervical versus metacarpus area. Light penetration was greater in both kinds of skins in the PBMT (0.01303 ± 0.00778) versus class IV laser (0.00122 ± SD 0.00070) (P < .001). The PBMT device provided a greater energy penetration than the class IV laser in unclipped light and dark skin, suggesting that the former may produce a better therapeutic effect. The color of the skin changes penetration profiles of PBMT.
| Reference Key |
luna2020penetrationjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Luna, Stelio Pacca Loureiro;Schoen, Allen;Trindade, Pedro Henrique Esteves;Rocha, Paula Barreto da; |
| Journal | journal of equine veterinary science |
| Year | 2020 |
| DOI |
S0737-0806(19)30595-7
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.