Azo-linked porous organic polymers/polydimethylsiloxane coated stir bar for extraction of benzotriazole ultraviolet absorbers from environmental water and soil samples followed by high performance liquid chromatography-diode array detection.
Clicks: 347
ID: 81879
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
347 views
47 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #13 of 58 articles by views in journal of chromatography a
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
With 4,4'-diaminoterphenyl and phloroglucinol as the monomers, Azo-linked porous organic polymer (PP) was prepared by a green mild azo reaction. Azo-PP is rich in phenolic hydroxyl groups and benzene rings, which can form intermolecular hydrogen bonds with the phenolic hydroxyl groups in interest benzotriazoles (BZTs). The π-π interaction between the benzene ring and the triazole ring would promote the adsorption of target BZTs on Azo-PP. Azo-PP/polydimethylsiloxane (PDMS) coated stir bar was prepared via sol-gel technique for the extraction of target BZTs. Compared with commercial stir bar, Azo-PP coated stir bar showed superior extraction efficiency (75-88% vs 45-65%) under similar conditions and kinetics (50 min vs 120 or 360 min). A method of stir bar sorptive extraction (SBSE) combined with high performance liquid chromatography (HPLC)-diode array detector (DAD) was developed to analyze six target BZT UltraViolet (UV) absorbers. The optimization of SBSE conditions for extraction of interest BZTs was performed by single-factor test. Under the optimized conditions, the limits of detection within 0.12-0.33 μg/L were achieved for six BZT UV absorbers, with the linear range within 0.5-100 μg/L. The method was applied to detect six BZT UV absorbers in the East Lake water, Yangtze River water, and campus soil samples. No BZT was detected in any of the samples. The recoveries of target BZTs in spiked samples were found in the range of 94.9-118%, 96.2-118%, and 88.2-119%.
| Reference Key |
wang2019azolinkedjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Wang, Zhuo;He, Man;Chen, Beibei;Hu, Bin; |
| Journal | journal of chromatography a |
| Year | 2019 |
| DOI |
S0021-9673(19)31241-5
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.