Frameless Deep Brain Stimulation Surgery: A Single-Center Experience and Retrospective Analysis of Placement Accuracy of 220 Electrodes in a Series of 110 Patients.

Clicks: 423
ID: 80606
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #1 of 4 articles by views in stereotactic and functional neurosurgery

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Proper lead placement is considered one of the key factors in achieving a good clinical outcome in deep brain stimulation (DBS), but there is still considerable controversy surrounding the accuracy of the frameless in comparison to the frame-based technique.We report our single-center experience with DBS electrode placement to evaluate the accuracy of the frameless stereotactic system.We prospectively analyzed the data of 110 patients who underwent DBS surgery for Parkinson disease, dystonia, essential tremor, or refractory epilepsy. The final targets (FTs) of the 220 leads were: subthalamic nucleus, globus pallidus pars interna, ventralis intermedius nucleus, and anterior nuclei of thalamus in thalamus. A bilateral stereotactic approach using a combined identification of target based on preoperative images (MRI and CT scan fusion) and intra-operative micro-electrode recording (MER) were done. We collected and compared the coordinates of planned target (PT), the definitive expected target (ET) during MER, and the effective final location (FT) of the lead using the postoperative CT. Accuracy was assessed by both vector error (VE) and deviation from the PT.The mean and SD from PTs was 0.78 ± 0.43 mm in the x direction, 0.68 ± 0.41 mm in the y direction, and 0.76 ± 0.41 mm in the z direction. Global VE was 1.43 ± 0.37.Frameless systems appear to be a reliable and accurate technique.
Reference Key
eleopra2020framelessstereotactic Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Eleopra, Roberto;Rinaldo, Sara;Devigili, Grazia;Mondani, Massimo;D'Auria, Stanislao;Lettieri, Christian;Ius, Tamara;Skrap, Miran;
Journal stereotactic and functional neurosurgery
Year 2020
DOI
10.1159/000503335
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.