A constant postpacing interval in response to overdrive pacing with variable number of beats: An aid in the identification of entrainment for a particular pacing train during macroreentrant atrial tachycardias.

Clicks: 306
ID: 79711
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #7 of 12 articles by views in journal of cardiovascular electrophysiology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
When pacing trains with a constant cycle length (CL) but increasing number of beats are introduced during a macroreentrant atrial tachycardia (MAT), the postpacing interval (PPI) is expected to increase if entrainment does not occur but could be stable if entrainment occurs. We tested the ability of PPI analysis to detect entrainment.Synchronized pacing trains with increasing number of beats (1-20) were delivered from the coronary sinus (CS) and lateral right atrium (RA) at a CL 20 ms shorter than the MAT CL. Pacing trains were grouped in pairs differing by one-paced beat, and the ∆PPI measured.In an initial prospective cohort of 21 patients (48% had left atrial flutter) the mean ∆PPI was 21.3 ± 5.6 ms for pairs of pacing trains in which neither entrained the MAT and 2.8 ± 1.4 ms for those in which both entrained the MAT (P < .0001). Results were similar for common vs atypical flutter, PPI-TCL ≤30 ms vs PPI-TCL >30 ms, presence vs absence of antiarrhythmic drugs and faster vs slower MAT. When an index pacing train was compared to one with two-paced beats less, a PPI difference of <19 ms identified entrainment with 95% sensitivity and 98% specificity. In a validation cohort of 16 patients, this cut-off value resulted in sensitivity and specificity of 90% and 94%.A relatively constant ∆PPI in response to overdrive pacing with identical CL but different number of beats allows accurate discrimination between trains that entrained vs those which did not entrain a MAT.
Reference Key
arceluz2019ajournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Arceluz, Martín R;Barrio, Teresa;Castellanos, Eduardo;Salgado, Ricardo;García, Javier;Lázaro Rivera, Carla;Ortiz, Mercedes;Lucena Pardos, Irené;Almendral, Jesús;
Journal journal of cardiovascular electrophysiology
Year 2019
DOI
10.1111/jce.14196
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.