Can Venous Blood Gas Be Used as an Alternative to Arterial Blood Gas in Intubated Patients at Admission to the Emergency Department? A Retrospective Study.

Clicks: 265
ID: 79364
2019
Article Quality & Performance Metrics
Overall Quality Improving Quality
0.0 /100
Combines engagement data with AI-assessed academic quality
AI Quality Assessment
Not analyzed
Abstract
Blood gas analysis plays an important role in both diagnosis and subsequent treatment of critically ill patients in the emergency department and the ICU. Historically, arterial blood is predominantly used for blood gas analysis. The puncture is painful and complications may occur. The purpose of the present study was to evaluate the agreement between arterial and venous blood gas analysis and whether the sole use of venous blood gas analysis would have changed therapy.Adult patients who were intubated in the field and received an arterial and venous blood gas analysis within 15 mins after admission to the ED were eligible for inclusion. The values for pH, pCO, HCO-, base excess and lactate levels were collected retrospectively. Mean differences were calculated by subtracting venous from arterial values. The agreement between venous and arterial measurements was assessed using the method of Bland and Altman. Blood gases were assessed by two independent physicians using a standardized questionnaire to determine whether the use of venous blood gases would have led to a different interpretation of the situation (other diagnostic path) or a change of therapy (eg. respirator adjustment). Acceptable limits were defined before the collection of data started.Fifty patients (62% male, median age 63years) who were treated at the Emergency Department between June 1, 2014 and December 31, 2014 were included in the study. Following average differences and limits of agreement (LOA) were documented: pH 0.02312 with LOA from -0.048 to 0.094; pCO -3.612 mmHg with LOA from -15 to 8.1 mmHg; BE -0.154 mmol/l with LOA from -3.7 to 3.4 mmol/l; HCO-0.338 mmol/l with LOA from -2.27 to 2.9 mmol/l; Lactate -0.124 mg/dl with LOA from -2.28 to 2.03 mg/dl. Using venous blood gas results 100% of the patients with metabolic alkalosis were correctly diagnosed. Metabolic acidosis was detected with a high sensitivity (80.64%), specificity (89.47%) and positive predictive value (92.59%). The answers to lactate and acidosis due to AKI showed a specificity and positive predictive value of 100%. The respiratory adjustment showed a high sensitivity (91.89%) but a low specificity (38.46%).For pH, bicarbonate, BE and lactate venous blood gases can be used as surrogates for arterial measurements. Venous pCO can be used for screening of hypercapnia and trending. Respirator adjustments may be done too often if the venous blood gas is used.
Reference Key
schutz2019canopen Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Schütz, Nikola;Roth, Dominik;Schwameis, Michael;Röggla, Martin;Domanovits, Hans;
Journal open access emergency medicine : oaem
Year 2019
DOI
10.2147/OAEM.S228420
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.