A visual system model and a new distortion measure in the context of image processing.
Clicks: 322
ID: 79071
1978
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
59.9
/100
322 views
209 readers
Trending
AI Quality Assessment
Not analyzed
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Underlying many techniques of image restortation, quantization, and enhancement is the mathematically convenient, but visually unsuitable distortion measure of squared difference in intensity. Squared-intensity differences has an indirect phenomenological correspondence in a model of the visual system. We have undertaken, therefore, an experiment that derives a new distortion measure from an acceptable visual system model and compares it in a fair test against squared difference in intensity in an image restoration task. We start with an eye-brain system model inferred from the works of current vision researchers, which consists of a bank of paralles spatial frequency channels and image detectors. From this model we derive a new distortion criterion that is related to changes in the per-channel detection probability and phase angle. The optimal linear (Wiener) filters for each distortion measure operate in turn on the same noisy incoherent images. The results show that the filter for the new distortion measures yields a superior restoration. It is more visually agrreable, more sharply detailed, and truer in contrast compared to the squared-difference filter, and impressive in its own right. Its mathematical properties suggest that significantly increased efficeincy in the storage or communication of images my be gained by its use.
| Reference Key |
pearlman1978ajournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Pearlman, W A; |
| Journal | journal of the optical society of america |
| Year | 1978 |
| DOI |
DOI not found
|
| URL | URL not found |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.