Effective Analgesia with Bilateral Erector Spinae Plane Catheters for a Patient with Traumatic Rib and Spine Fractures
Clicks: 426
ID: 7904
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
78.0
/100
426 views
314 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #1 of 24 articles by views in case reports in anesthesiology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Pain management in trauma patients with acute rib and spine fractures presents a challenge for the anesthesiologist and achieving adequate analgesia is important in preventing pulmonary complications. Unfortunately, neuraxial techniques are often challenging or contraindicated due to spine fractures or coagulopathy. Erector spinae plane (ESP) blocks provide an alternative regional anesthetic technique to manage pain. We describe a case of bilateral ESP catheters placed intraoperatively after spinal instrumentation in a patient with bilateral rib and spine fractures sustained in a tractor rollover crash. Prior to surgery, the patient had inadequate pain control and poor respiratory function despite multimodal analgesia. With the addition of bilateral ESP catheters, the patient’s pain control improved and he was weaned from respiratory support. ESP blocks have been shown to provide effective analgesia in patients with rib fractures; however, the utilization of these blocks has not been described in patients with spine fractures undergoing spinal instrumentation. Thus, ESP blocks provide a simple alternative to providing surgical and trauma analgesia when neuraxial techniques are contraindicated. The success of bilateral ESP catheters in our patient indicates a further area for application of ESP blocks in patients undergoing spine surgery with acute traumatic spine fractures.
| Reference Key |
l2019effectivecase
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Klesius, L.;Schroeder, K.;Klesius, L.;Schroeder, K.; |
| Journal | case reports in anesthesiology |
| Year | 2019 |
| DOI |
10.1155/2019/9159878
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.