Effect of Image Resolution and Compression on Fractal Analysis of the Periapical Bone.

Clicks: 435
ID: 78694
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady
Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Fractal dimension (FD) on periapical radiographs is used as a simple descriptor of the complex architecture of the trabecular bone surrounding the dentition. It is used on periapical and panoramic radiographs as a descriptor of the complex architecture of trabecular bone surrounding teeth.The aim of this study was to evaluate the effect of image resolution and different compression levels on fractal dimension of alveolar bone with images obtained using storage phosphor plate (SPP) system.Periapical images of premolar and molar teeth on both sides of three dry human mandibles were obtained with Digora Optime (Soredex Corp., Helsinki, Finland) SPP system. The SPPs were exposed equally and scanned immediately after exposure with standard, high and very high resolutions. All the images then were compressed and saved by degrees of 0%, 25%, 50%, 75% and 90%. FD was calculated using public domain software (ImageJ with FracLac plug-in) on two non-overlapping regions of interest (ROIs) on premolar and molar periapical bone areas of each radiograph using differential box-counting method. The ROIs on corresponding images were of the same size and position. FDs were compared using two-way ANOVA and Tukey-Kramer multiple comparison tests (p=0.05).There was no significant difference in FD calculations in different levels of compression for all the resolutions. Images obtained with high resolution scans showed significantly lower variation in FD values compared to very high and standard resolutions for all compressions (p<0.0001).The high resolution demonstrated the lowest variation in FD values in all levels of compression which makes it the most reliable and consistent resolution for measuring the FD values. The level of compression does not make a significant difference in FD values for all the scan resolutions. Scanning resolution of SPPs should be carefully chosen when evaluating the change in FD of alveolar bone for various bone disorders.
Reference Key
toghyani2019effectacta Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Toghyani, Shiva;Nasseh, Ibrahim;Aoun, Georges;Noujeim, Marcel;
Journal Acta informatica medica : AIM : journal of the Society for Medical Informatics of Bosnia & Herzegovina : casopis Drustva za medicinsku informatiku BiH
Year 2019
DOI
10.5455/aim.2019.27.167-170
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.