Clinical outcomes of high-risk labours monitored using fetal electrocardiography.
Clicks: 310
ID: 78389
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
81.7
/100
310 views
214 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 3 articles by views in annals of the academy of medicine, singapore
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The aim of the study was to review clinical and laboratory outcomes of a cohort of fetuses monitored during high-risk labours, simultaneously by fetal electrocardiography (FECG) and routine cardiotocography (CTG).Eighty-three parturients from the Department of Obstetrics and Gynecology of Medical University were included in the clinical study. Inclusive criteria to the study group were: (i) singleton pregnancy at term (between 37 and 42 weeks' gestation), (ii) longitudinal fetal lying, (iii) more than 2500 g of estimated fetal weight, (iv) meconium-stained liquor, and (v) induction of labour due to fetal indications. Fetal outcome parameters analysed included Apgar scores at 1st, 5th and 10th minute after birth, cord artery acid-base assessment and lactate concentrations analysis. FECG was performed during labour, until the neonate was born, with the use of single spiral scalp electrode connected to the STAN S21 heart monitor. Immediately after delivery, arterial cord blood gas and venous cord blood lactate's concentrations were analysed.The sensitivity (100%), specificity (97%), negative predictive value (NPV) (100%) and positive predictive value (33%) were higher for FECG than for CTG. Moreover, several significant correlations between episodic/baseline T/QRS ratio rises and cord artery acid-base as well as lactate concentrations were demonstrated.Correlations between episodic/baseline T/QRS ratio rises and fetal outcome parameters indicate that observed changes in FECG reflect neonatal metabolic lactate acidosis. The high sensitivity, specificity and especially very high NPV are proof that FECG serves as a reliable method for electronic fetal monitoring during high-risk labours.
| Reference Key |
rzepka2010clinicalannals
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Rzepka, Rafal;Torbé, Andrzej;Kwiatkowski, Sebastian;Blogowski, Wojciech;Czajka, Ryszard; |
| Journal | annals of the academy of medicine, singapore |
| Year | 2010 |
| DOI |
DOI not found
|
| URL | URL not found |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org