Enhanced Load Power Sharing Accuracy in Droop-Controlled DC Microgrids with Both Mesh and Radial Configurations
Clicks: 264
ID: 77375
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
71.3
/100
264 views
212 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #74 of 220 articles by views in energies
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 220 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The rational power sharing among different interface converters should be determined by the converter capacity. In order to guarantee that each converter operates at the ideal condition, considering the radial and mesh configuration, a modified strategy for load power sharing accuracy enhancement in droop-controlled DC microgrid is proposed in this paper. Two compensating terms which include averaging output power control and averaging DC voltage control of neighboring converters are employed. Since only the information of the neighboring converter is used, the complexity of the communication network can be reduced. The rational distribution of load power for different line resistance conditions is realized by using modified droop control that can be regarded as a distributed approach. Low bandwidth communication is used for exchanging sampled information between different converters. The feasibility and effectiveness of the proposed method for different network configurations and line resistances under different communication delay is analyzed in detail. Simulation results derived from a DC microgrid with three converters is implemented in MATLAB/Simulink to verify the proposed approach. Experimental results from a 3 × 10 kW prototype also show the performance of the proposed modified droop control scheme.
| Reference Key |
liu2015enhancedenergies
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Liu, Yiqi;Wang, Jianze;Li, Ningning;Fu, Yu;Ji, Yanchao; |
| Journal | energies |
| Year | 2015 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Engineering (General). Civil engineering (General)
Information technology
Technology
Computer applications to medicine. Medical informatics
Science (General)
applied optics. photonics
electronic computers. computer science
colonies and colonization. emigration and immigration. international migration
|
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.