Development of Uric Acid Biosensor Biosensor using Gold Nanoparticles and Graphene Oxide Functionalized Micro-Ball Fiber Sensor Probe.
Clicks: 375
ID: 77279
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
77.2
/100
375 views
256 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #2 of 5 articles by views in IEEE Transactions on NanoBioscience
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A highly sensitive and selective optical fiber-based enzymatic biosensor has been proposed in the present study for detection of uric acid (UA) in human serum. The working mechanism of sensor depends on surface plasma property and localized surface plasmon resonance technique. For this purpose, a micro-ball fiber sensor probe of 350 μm diameter was fabricated using advanced fusion-splicer and coated with gold nanoparticles (AuNPs) and graphene oxide (GO) in order to enhance its sensitivity. UV-Visible spectrophotometer and high-resolution transmission electron microscope (HR-TEM) were used to characterize the AuNPs solution and GO aqueous dispersion. The absorbance spectrum of AuNPs and GO are recorded at 519 nm and 230 nm, respectively. The coating of AuNPs and GO over fiber surface were verified by using a scanning electron microscope (SEM) and energy-dispersive X-ray spectroscopy (EDX). Thereafter, sensor probe was functionalized with the specific enzyme i.e. uricase for the UA detection. The linearity response of uricase/GO/AuNPs-coated micro-ball optical fiber sensor is reported in the range of 10 μM - 1 mM UA concentrations. The reflectance of sensor linearly decreases with the increasing UA concentrations. Sensitivity of the sensor is 2.1 %/mM with a good slope of linearity with detection limit of 65.60 μM. To test the accuracy of proposed sensor, UA concentration in serum samples have also tested by using proposed sensor and A5800 Automatic Biochemical Analyzer. The results of the developed sensor are consistent with the results of A5800 Automatic Biochemical Analyzer. Thus, proposed sensor can be successfully utilized for UA detection in human serum samples.
| Reference Key |
kumar2019developmentieee
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Kumar, Santosh;Singh, Ragini;Zhu, Guo;Yang, Qingshan;Zhang, Xia;Cheng, Shuang;Zhang, Bingyuan;Kaushik, Brajesh Kumar;Liu, Feng-Zhen; |
| Journal | IEEE Transactions on NanoBioscience |
| Year | 2019 |
| DOI |
10.1109/TNB.2019.2958891
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.