Multispectral diffusion-weighted MRI of the instrumented cervical spinal cord: a preliminary study of 5 cases.
Clicks: 351
ID: 77277
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
65.4
/100
351 views
234 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 4 articles by views in european spine journal : official publication of the european spine society, the european spinal deformity society, and the european section of the cervical spine research society
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Diffusion-weighted imaging has undergone substantial investigation as a potential tool for advanced assessment of spinal cord health. Unfortunately, commonly encountered surgically implanted spinal hardware has historically disrupted these studies. This preliminary investigation applies the recently developed multispectral diffusion-weighted PROPELLER technique to quantitative assessment of the spinal cord immediately adjacent to metallic spinal fusion instrumentation.Morphological and diffusion-weighted MRI of the spinal cord was collected from 5 subjects with implanted cervical spinal fusion hardware. Conventional and multispectral diffusion-weighted images were also collected on a normative non-instrumented control cohort and utilized for methodological stability analysis. Variance of the ADC values derived from the normative control group was then analyzed on a subject-by-subject basis and qualitatively correlated with clinical morphological interpretations.Normative control ADC values within the spinal cord were stable across DWI methods for a b value of 600 s/mm, though this stability degraded at lower b value levels. Susceptibility artifacts precluded conventional DWI analysis of the cord in subjects with spinal fusion hardware in 4 of the 5 test cases. On the contrary, multispectral PROPELLER DWI produced viable ADC measurements within the cord of all 5 instrumented subjects. Instrumented cord regions without obvious pathology (N = 4) showed ADC values that were lower than expected, whereas one subject with diagnosed myelomalacia showed abnormally elevated ADC.In the absence of instrumentation, multispectral DWI provides quantitative capabilities that match with those of conventional DWI approaches. In a preliminary instrumented subject analysis, cord ADC values showed both expected and unexpected variations from the normative cohort. These slides can be retrieved under Electronic Supplementary Material.
| Reference Key |
koch2019multispectraleuropean
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Koch, Kevin M;Bhave, Sampada;Kaushik, S Sivaram;Nencka, Andrew S;Budde, Matthew D; |
| Journal | european spine journal : official publication of the european spine society, the european spinal deformity society, and the european section of the cervical spine research society |
| Year | 2019 |
| DOI |
10.1007/s00586-019-06239-z
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.