Electrochemical Detection of Fertility Hormones.
Clicks: 292
ID: 77028
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
67.7
/100
292 views
223 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 2 articles by views in critical reviews in biomedical engineering
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Fertility hormone levels are constantly changing, but it is crucial for a woman to be able to monitor her fertility levels if she is interested in conceiving. Women and physicians often have a difficult time determining ovulation windows due to fluctuating menstrual cycles and inaccurate interpretations of hormone levels. Current methods of fertility monitoring include physical or vaginal exams, laparoscopy, ultrasound scans, as well as evaluation of hormone levels. A rapid, at-home fertility monitoring tool can help alleviate the apprehensiveness associated with routine screenings and give women the privacy desired when trying to conceive. Herein, we discuss the development of an electrochemical biosensor for quantification of three fertility hormones: beta-estradiol, progesterone, and FSH. Each biomarker's MRE was immobilized onto a gold disk electrode through the use of self-assembled monolayer linking chemistry. Using electrochemical impedance spectroscopy (EIS), the biomarker concentration was correlated to impedance magnitude. An optimal binding frequency was identified for each biomarker, permitting simplistic hardware requirements and investigation into multimarker detection. Analytes were tested in both purified solutions and 1%-90% whole blood. Each biomarker exhibited a unique imaginary impedance peak and optimal binding frequency. The determination was made by assessing the response parameters including the linear fit correlation across the physiological hormone ranges. The existence of unique optimal frequencies permits for simultaneous detection of multiple hormones in a single test. Additionally, the identified frequency was robust across purified and complex solutions. Response characteristics were negatively impacted by the introduction of blood-based contaminants. However, the introduction of Nafion membranes, similar to ones used in commercial glucose sensors, is both feasible and beneficial.
| Reference Key |
khanwalker2019electrochemicalcritical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Khanwalker, Mukund;Johns, Jared;Honikel, Mackenzie M;Smith, Victoria;Maxwell, Stephanie;Santhanaraman, Sandhya;La Belle, Jeffrey T; |
| Journal | critical reviews in biomedical engineering |
| Year | 2019 |
| DOI |
10.1615/CritRevBiomedEng.2019026545
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.