Digital microfluidic meter-on-chip.
Clicks: 110
ID: 76747
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
57.6
/100
110 views
75 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #17 of 18 articles by views in lab on a chip
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The accurate monitoring and control of liquid flow at low flow rates have become increasingly important in contemporary biomedical research and industrial monitoring. Inspired by the drop-counting principle implemented in a clinical gravity drip, we propose a novel microfluidic flowmetry technology for polydimethylsiloxane (PDMS)-based conventional microfluidic devices, known as a microfluidic digital meter-on-chip (DMC), to achieve on-chip and localized microflow measurements with ultrahigh precision and a wide tunable range. The DMC technology primarily relies on capillarity, unlike a gravity drip, to induce a characteristic interfacial droplet pinch-off process, from which digital microflowmetry devices can discretize continuous flow into countable transferred liquid units with consistent quantifiable volumes. Enabled by the passive discretization principle and optical transparency, the DMC device requires no external energy input or bulky control equipment, and a non-contact wireless optical detection scheme using a smartphone can be conveniently used as a readout module. Moreover, the DMC technology achieves an ultrahigh flow-to-frequency sensitivity (6.59 Hz (μL min-1)-1) and resolution (droplet transfer volume down to 2.5 nL, nearly two orders of magnitude smaller than in previously reported work, resulting in ultralow flow rates of 1 μL min-1). In addition, the flow rate measurement range covers up to 80 μL min-1 and down to at least 150 nL min-1 (over 100 times lower than reported similar digital flowmetry on the same time scale) using the current device configuration. Benefiting from its simple device architecture and adaptability, the versatile DMC technology can be seamlessly integrated with various microfluidic and nanofluidic devices for drug delivery and biochemical analysis, serving as a promising technology platform for next-generation highly demanding microflow measurements.
| Reference Key |
fang2019digitallab
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Fang, Zecong;Ding, Yi;Zhang, Zhichao;Wang, Fei;Wang, Zuankai;Wang, Hao;Pan, Tingrui; |
| Journal | lab on a chip |
| Year | 2019 |
| DOI |
10.1039/c9lc00989b
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.