Metal ions-based immunosensor for simultaneous determination of estradiol and diethylstilbestrol.
Clicks: 459
ID: 76651
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
83.4
/100
459 views
322 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #7 of 85 articles by views in Biosensors & bioelectronics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Environmental estrogens (EEs) can cause various endocrine diseases. Herein, we designed an ultrasensitive electrochemical immunosensor for simultaneous detection of two typical EEs, estradiol and diethylstilbestrol. These two analytes were immobilized on graphene sheet (GS) modified glassy carbon electrode (GCE). Amino-group functionalized mesoporous Fe3O4 (Fe3O4-NH2) was loaded with Pb(2+) or Cd(2+), and then incubated with estradiol and diethylstilbestrol antibodies, respectively. Using an electrochemical analysis technique, two well-separated peaks were generated by the redox reaction of Pb(2+) or Cd(2+), making the simultaneous detection of two analytes on the electrode possible. Subsequently, square wave anodic stripping voltammetry (SWASV) and electrochemical impedance spectroscopy (EIS) were used to investigate the electrochemical behaviors of the immunosensor. Under optimized conditions, the SWASV peak currents were proportional to the concentrations of estradiol and diethylstilbestrol in the range from 0.050 pg mL(-1) to 100 ng mL(-1) and 1.0 pg mL(-1) to 100 ng mL(-1), respectively. The immunosensor exhibited highly sensitive response to estradiol with a detection limit of 0.015 pg mL(-1) and diethylstilbestrol with a detection limit of 0.38 pg mL(-1). Furthermore, the immunosensor was satisfactorily employed to detect estradiol and diethylstilbestrol simultaneously in water samples.
| Reference Key |
zhang2014metalbiosensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zhang, Sen;Du, Bin;Li, He;Xin, Xiaodong;Ma, Hongmin;Wu, Dan;Yan, Liangguo;Wei, Qin; |
| Journal | Biosensors & bioelectronics |
| Year | 2014 |
| DOI |
10.1016/j.bios.2013.08.042
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.