Magnetic sensing film based on Fe₃O₄@Au-GSH molecularly imprinted polymers for the electrochemical detection of estradiol.
Clicks: 296
ID: 76645
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
65.3
/100
296 views
185 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #36 of 85 articles by views in Biosensors & bioelectronics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A novel magnetic molecularly imprinted sensing film (MMISF) was fabricated for the determination of estradiol (E2) based on magnetic glassy carbon electrode (MGCE) and magnetic molecularly imprinted polymers (MMIPs). The MMIPs were synthesized by in situ polymerization of glutathione (GSH)-functionalized gold (Au)-coated Fe3O4 (Fe3O4@Au-GSH) nanocomposites and aniline. The MMISF was constructed with MMIPs via a kind of "soft modification" where MMIPs were assembled and immobilized on the surface of MGCE or removed from it by freely installing a magnet into MGCE or not. The E2-MMIPs were obtained by MMIPs recognizing E2 from sample, and the electrochemical detection was carried out after forming the "soft modification" sensing film by putting MGCE into the E2-MMIPs suspension liquid. Afterwards, the "soft modification" MMISF was peeled off from the electrode by removing the magnet from MGCE. The interface of the electrode could be quickly refreshed through simple treatment for the next detection. The structures and morphologies of Fe3O4@Au-GSH, MMIPs and MMISF were investigated by Fourier transform infrared spectrometer, ultraviolet and visible spectrophotometer, scanning electron microscope and atomic force microscope. In addition, the MMISF was successfully used for detecting E2 in milk powder with good sensitivity, selectivity, reproducibility and efficiency. The linear range of the MMISF for E2 was 0.025-10.0μmolL(-1) with the limit of detection of 2.76nmolL(-1) (S/N= 3).
| Reference Key |
han2016magneticbiosensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Han, Qing;Shen, Xin;Zhu, Wanying;Zhu, Chunhong;Zhou, Xuemin;Jiang, Huijun; |
| Journal | Biosensors & bioelectronics |
| Year | 2016 |
| DOI |
10.1016/j.bios.2015.12.017
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org