Tailoring MWCNTs and β-Cyclodextrin for Sensitive Detection of Acetaminophen and Estrogen.
Clicks: 388
ID: 76639
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
63.6
/100
388 views
246 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #33 of 899 articles by views in ACS applied materials & interfaces
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 899 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Monitoring of trace amount of acetaminophen and estrogen in drinking water is of great importance because of their potential links to gastrointestinal diseases and breast and prostate cancers. The sensitive and accurate detection of acetaminophen and estrogen requires the development of advanced sensing materials that possess appropriate number of analyte-capturing sites and suitable signal conduction path. This can be achieved by implementing appropriate chemical attachment of multiwalled carbon nanotubes (MWCNTs) and β-cyclodextrin (βCD). Here, we report a systematic investigation of four types of modified MWCNT-βCD: (1) physical mixing, (2) "click reaction", (3) thionyl chloride esterification, and (4) Steglich esterification. The Steglich esterification is a one-step approach with shorter reaction time, lower reaction temperature, and eliminates handling of air/moisture-sensitive reagents. MWCNT-βCD prepared by Steglich esterification possessed moderate βCD loading (5-10 wt %), large effective surface area, and fast electron transfer. The host-guest interaction of βCD and redox properties of MWCNT enabled sensitive detection of acetaminophen and 17β-estradiol (E2 is a primary female sex hormone) in the range of 0.005-20 and 0.01-15 μM, with low detection limits of 3.3 and 2.5 nM, respectively. We demonstrated accurate detection results of pharmaceutical compositions in water and urine samples. These results indicate that Steglich esterification method may be applied in fabricating pharmaceutical contaminants sensors for health and environmental applications.
| Reference Key |
alam2018tailoringacs
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Alam, Arif Ul;Qin, Yiheng;Catalano, Massimo;Wang, Luhua;Kim, Moon J;Howlader, Matiar M R;Hu, Nan-Xing;Deen, M Jamal; |
| Journal | ACS applied materials & interfaces |
| Year | 2018 |
| DOI |
10.1021/acsami.8b04639
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.