Doping of transition metal dichalcogenides in molecularly imprinted conductive polymers for the ultrasensitive determination of 17β-estradiol in eel serum.
Clicks: 353
ID: 76632
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
67.5
/100
353 views
241 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #22 of 85 articles by views in Biosensors & bioelectronics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Molecularly imprinted polymers (MIPs) have been developed to replace antibodies for the recognition of target molecules (such as antigens), and have been integrated into electrochemical sensing approaches by polymerization onto an electrode. Electrochemical sensing is inexpensive and flexible, and has demonstrated utility in point-of-care devices. In this work, several 2D (conductive) materials were employed to improve the performance of MIP sensors. Screen-printed electrodes were coated by the electropolymerization of aniline and metanilic acid, commingled with target molecules and various 2D materials. Tungsten disulfide (WS) with an average particle size of 2 μm was found to increase the sensitivity of detection of molecularly imprinted conductive polymer-coated electrodes to 17β-estradiol. As estradiol concentrations are important to eel aquaculture, we screened eel serum samples to determine their 17β-estradiol concentrations, which were found to be in the range 28.2 ± 3.6 to 73.0 ± 11.6 pg/mL after dilution. These results were in agreement with measurements using commercial immunoanalysis.
| Reference Key |
lee2019dopingbiosensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Lee, Mei-Hwa;Thomas, James L;Su, Zi-Lin;Zhang, Zheng-Xiang;Lin, Chu-Yun;Huang, Yung-Sen;Yang, Chien-Hsin;Lin, Hung-Yin; |
| Journal | Biosensors & bioelectronics |
| Year | 2019 |
| DOI |
S0956-5663(19)30980-7
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org