Solvent bar microextraction using a reverse micelle containing extraction phase for the determination of warfarin from human plasma by high-performance liquid chromatography.
Clicks: 238
ID: 76273
2017
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Steady Performance
81.6
/100
237 views
187 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
For the first time, solvent bar microextraction using a reverse micelle RMM-SBME as extraction phase was developed for extraction of warfarin in human plasma sample. The reverse micelle of a cationic surfactant (hexadecyltrimethylammonium bromide) in 1-octanol was applied as supported and acceptor phase in SBME. In this process, the analyte was extracted from aqueous samples into a reverse micelle impregnated and also filled in the wall pores and lumen the polypropylene hollow fiber membrane by the electrostatic interactions between the analyte and the surfactant head groups. The influences of fundamental parameters affecting extraction efficiency of warfarin including sample solution pH, surfactant concentration and extraction time were studied using central composite design optimization method. The analysis of extracted analyte was performed by high performance liquid chromatography with ultra violet detector. Under the optimum condition, the sample containing 40ngmL of warfarin was extracted with extraction recovery of 97.8% that pertained to enrichment factor of 260. A good linearity over a concentration range 1-600ngmL with correlation coefficient value of 0.9989 was provided by the current method. Limits of detection and inner and inter-day relative standard deviation were 0.3ngmL and less than 4.4%, respectively. This method was compared to conventional SBME, and illustrated higher extraction efficiency. The method needs minimal sample preparation time since the porous hollow fiber membrane prevents from being extracted potential interfering materials, acts as a filter, and any extra cleanup was not required. The method with bar of 3cm and acceptor phase volume of 8.5μL is environmentally green/friendly method. The proposed method was successfully applied for the preconcentration and determination of warfarin in plasma sample.
Abstract Quality Issue:
This abstract appears to be incomplete or contains metadata (263 words).
Try re-searching for a better abstract.
| Reference Key |
ranjbar-bandforuzi2017solventjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ranjbar Bandforuzi, Samereh;Hadjmohammadi, Mohammad Reza; |
| Journal | journal of chromatography a |
| Year | 2017 |
| DOI |
S0021-9673(17)30416-8
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.