First Report on a Solvent-Free Preparation of Polymer Inclusion Membranes with an Ionic Liquid.
Clicks: 326
ID: 76267
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
77.3
/100
326 views
186 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #234 of 729 articles by views in molecules
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 729 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A novel and environmentally-friendly procedure for the preparation of polymer inclusion membranes (PIMs) containing an ionic liquid is presented for the first time. Traditionally, PIMs are prepared by a solvent casting method with the use of harmful organic solvents. Here we report a new solvent-free procedure based on a thermal-compression technique which involve the melting of the components of the PIM and the application of a high pressure to the melted specimen to form a flat-sheet film. In our study, we have tested different polymers, such as two cellulose derivatives as well as two thermoplastic polymers, polyurethane (TPU) and poli ε-caprolactone (PCL). The ionic liquid (IL) trioctylmethylammonium chloride (Aliquat 336) has been used to produce PIMs with a fixed composition of 70% polymer-30% IL (/). Both TPU and PCL polymers provide successful membranes, which have been thoroughly characterized. PIMs based on the polymer PCL showed a high stability. To test whether the properties of the IL were affected by the preparation conditions, the extraction ability of Aliquat 336 was investigated for both PCL and TPU membranes in terms of Cr(VI) extraction. Satisfactory values (90% extraction) were obtained for both membranes tested, showing this novel procedure as a green alternative for the preparation of PIMs with ILs.
| Reference Key |
vera2019firstmolecules
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Vera, Ruben;Anticó, Enriqueta;Eguiazábal, José Ignacio;Aranburu, Nora;Fontàs, Clàudia; |
| Journal | molecules |
| Year | 2019 |
| DOI |
E1845
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.