A Proposed Waterpipe Emissions Topography Protocol Reflecting Natural Environment User Behaviour.

Clicks: 344
ID: 76172
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #201 of 862 articles by views in International journal of environmental research and public health

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 862 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Usage of waterpipes is growing in popularity around the world. Limited waterpipe natural environment topography data reduces the ability of the research community to accurately assess emissions and user exposure to toxicants. A portable ergonomic waterpipe monitor was provided to study participants to use every time they smoked their own waterpipe during a one-week monitoring period in conjunction with their own choice shisha tobacco. Users provided demographic information and logged their product use to supplement electronic monitor data. A total of 44 prospective study participants were invited to an intake appointment following an on-line pre-screening survey. Of these, 34 individuals were invited to participate in the study and data for 24 individuals who completed all aspects of the 1-week monitoring protocol is presented. 7493 puffs were observed during 74 waterpipe sessions accumulating over 48 h of waterpipe usage. The 95% CI on mean puff flow rate, duration, volume and interval are presented, yielding grand means of 243 [mL/s], 3.5 [s], 850 [mL], and 28 [s] respectively. The middle 95% of puff flow rates ranged between 62 to 408 [mL/s], durations from 0.8 to 6.8 [s], and puff volumes from 87 to 1762 [mL]. A waterpipe emissions topography protocol consisting of 13 flow conditions is proposed to reflect 93% of the observed range of puff flow rate, puff duration and puff volume with representative inter-puff interval, cumulative session time and aerosol volumes.
Reference Key
hensel2019ainternational Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Hensel, Edward C;Sarles, Samantha Emma;Al-Olayan, Abdulaziz;DiFrancesco, A Gary;Jayasekera, Shehan;Eddingsaas, Nathan C;Robinson, Risa J;
Journal International journal of environmental research and public health
Year 2019
DOI
E92
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.