Effect of Ventilation Improvement during a Tuberculosis Outbreak in Underventilated University Buildings.

Clicks: 360
ID: 75522
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #3 of 10 articles by views in indoor air

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The role of ventilation in preventing tuberculosis (TB) transmission has been widely proposed in infection control guidance. However, conclusive evidence is lacking. Modelling suggested the threshold of ventilation rate to reduce effective reproductive ratio (ratio between new secondary infectious cases and source cases) of TB to below 1 is corresponding to a CO level of 1,000 parts per million (ppm). Here, we measured the effect of improving ventilation rate on a TB outbreak involving 27 TB cases and 1,665 contacts in underventilated university buildings. Ventilation engineering decreased the maximum CO levels from 3,204 ± 50 ppm to 591-603 ppm. Thereafter, the secondary attack rate of new contacts in university dropped to zero (mean follow-up duration: 5.9 years). Exposure to source TB cases under CO >1,000 ppm indoor environment was a significant risk factor for contacts to become new infectious TB cases (P<0.001). After adjusting for effects of contact investigation and latent TB infection treatment, improving ventilation rate to levels with CO <1,000 ppm was independently associated with a 97% decrease (95% CI: 50%-99.9%) in the incidence of TB among contacts. These results show that maintaining adequate indoor ventilation could be a highly effective strategy for controlling TB outbreaks.
Reference Key
du2019effectindoor Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Du, Chun-Ru;Wang, Shun-Chih;Yu, Ming-Chih;Chiu, Ting-Fang;Wang, Jann-Yuan;Chuang, Pei-Chun;Jou, Ruwen;Chan, Pei-Chun;Fang, Chi-Tai;
Journal indoor air
Year 2019
DOI
10.1111/ina.12639
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.