An Improved Proposed Single Phase Transformerless Inverter with Leakage Current Elimination and Reactive Power Capability for PV Systems Application
Clicks: 382
ID: 75145
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
68.9
/100
382 views
272 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 4 articles by views in journal of low power electronics and applications
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Single-phase transformerless inverters are broadly studied in literature for residential-scale PV applications due to their great advantages in reducing system weight, cost and elevating system efficiency. The design of transformerless inverters is based on the galvanic isolation method to eliminate the generation of leakage current. Unfortunately, the use of the galvanic isolation method alone cannot achieve constant common mode voltage (CMV). Therefore, a complete elimination of leakage current cannot be achieved. In addition, modulation techniques of single-phase transformerless inverters are designed for the application of the unity power factor. Indeed, next-generation PV systems are required to support reactive power to enable connectivity to the utility grid. In this paper, a proposed single-phase transformerless inverter is modified with the clamping method to achieve constant CMV during all inverter operating modes. Furthermore, the modulation technique is modified by creating a new current path in the negative power region. As a result, a bidirectional current path is created in the negative power region to achieve reactive power generation. The simulation results show that the CMV is completely clamped at half the DC link voltage and the leakage current is almost completely eliminated. Furthermore, a reactive power generation is achieved with the modified modulation techniques. Additionally, the total harmonic distortion (THD) of the grid current with the conventional and a modified modulation technique is analyzed. The efficiency of the system is enhanced by using wide-bandgap (WBG) switching devices such as SiC MOSFET. It is observed that the efficiency of the system decreased with reactive power generation due to the bidirectional current path, which leads to increasing conduction losses.
| Reference Key |
almasoudi2018anjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Almasoudi, Fahad;Matin, Mohammad; |
| Journal | journal of low power electronics and applications |
| Year | 2018 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.