A novel electrochemical sensor based on ion imprinted polymer and gold nanomaterials for nitrite ion analysis in exhaled breath condensate.
Clicks: 489
ID: 74215
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
489 views
60 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #6 of 391 articles by views in Talanta
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 391 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Human Exhaled Breath Condensate (EBC) contains markers of several inflammatory diseases. Its analysis is of interest to a number of researchers. Nitrite ions (NO-), which are widely used in our daily lives, are nevertheless among these indicators. In this study, a simple, fast, portable, non-invasive and cheap electrochemical sensor is developed for the analysis of the nitrite profile in EBC. In this regard, sodium nitrite (NaNO) was first immobilized on self-assembled 2-aminothiophenol (2-ATP) on a screen-printed gold electrode (Au-SPE). Then, a polymer matrix composed of polyvinyl alcohol (PVA) crosslinked with glutaraldehyde (GA) was combined with gold nanoparticles (Au-NPs) to cover the modified Au-SPE and complete the fabrication of the Ion Imprinted Polymer (IIP) sensor. The electrochemical behaviour of the sensor was monitored using Cyclic Voltammetry (CV), Electrochemical Impedance Spectroscopy (EIS) and Differential Pulse Voltammetry (DPV) methods, while the morphology and chemical composition of its layers were observed by infrared Fourier transform (FTIR), Atomic Force Microscopy (AFM) and Scanning Electron Microscopy coupled with energy dispersion X-Ray spectroscopy (SEM-EDS) techniques. In addition, after a successful control test using a Non-Imprinted Ion Polymer (NIIP) sensor, the obtained results demonstrated satisfactory sensitivity and selectivity to nitrite compared to co-existing interfering substances in EBC, such as nitrate, acetate and ammonium nitrate. Under improved experimental conditions, the nitrite IIP sensor exhibits responses proportional to nitrite concentrations (R = 0.96) over a concentration range of 0.5-50 μg mL with a detection limit (LOD) of 4 μmol L (signal-to-noise ratio S/N = 3). The proposed approach was well applied for the nitrite determination in EBC samples with a relative standard deviation (RSD = 4%) and could open clinical applications in respiratory medicine.
| Reference Key |
diouf2020atalanta
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Diouf, Alassane;El Bari, Nezha;Bouchikhi, Benachir; |
| Journal | Talanta |
| Year | 2020 |
| DOI |
S0039-9140(19)31210-X
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.